Duct Leakage Test in Pitman, NJ

Keep your HVAC system running at peak efficiency and in full compliance with local codes through expert duct leakage test in Pitman, NJ. Our certified technicians inspect and measure air leakage in ductwork, enabling homeowners and builders to boost comfort, prevent energy waste, and adhere to state guidelines.

Why Duct Leakage Test is Important In Pitman, NJ

In many jurisdictions, the 2015 IECC, International Energy Conservation Code governs single-family buildings, while the 2018 IECC applies to multi-family buildings. The change will have some significant implications for home builders and HVAC contractors operating in the state. A Duct Leakage Test together with a Blower Door Test has become mandatory for any newly constructed or remodeled home under the 2015 code. Did you know that ducts are a leading factor in home air leakage across Pennsylvania, New Jersey, and Delaware? Leaked air can drive up energy bills, put extra stress on your HVAC system, and circulate dust and insulation throughout your living space. This makes duct leakage test highly important for homes of any age. Read on to learn why duct leakage test matters and the benefits you can gain.

What Our Clients Say

How a Duct Leakage Test Is Conducted

To get started with a duct leakage test in Pitman, NJ, the technician will block every supply and return register except the main return or air handler. A specially calibrated fan called a duct blaster is then connected to the opening. This fan depressurizes the duct system, making it easier to pinpoint exactly where air is leaking.

The duct blaster works in sync with a precision pressure sensor to assess airflow and find duct leaks without disturbing your living space. A duct leakage test — widely known as a duct blaster test — pinpoints air leakage in your ducts so you can choose the best sealing methods.

duct leakage test is simple, clean, and minimally invasive for residents. Most tests in Pitman, NJ are done within 30 to 60 minutes, with improvements that strengthen comfort and efficiency for years to come.

How to Measure Duct Leakage

Duct leakage is measured using cubic feet per minute (CFM) per 100 square feet of conditioned floor area. Your technician uses a nanometer to identify subtle pressure differences, helping determine how much air is leaking from the ducts. Understanding this number allows you to pinpoint problem areas, assess needed improvements, and confirm whether your home satisfies local energy code requirements in Pitman, NJ.

Cost of Excessive Duct Leakage

If you’re facing higher energy bills, uneven heating or cooling, or recurring HVAC repairs, duct leakage could be to blame. According to ENERGY STAR, homes across the country lose 20% to 30% of their conditioned air through duct leakage. Outside hot or cold air leaking into your system puts extra strain on your HVAC unit, raising energy bills and decreasing comfort.

Overworked equipment also causes additional breakdowns and increases repair costs. Proper duct sealing helps support your HVAC system’s long-term operation, increasing its lifespan and lowering frequent maintenance needs.

Duct leaks can also let dust, mold spores, moisture, and other pollutants enter the duct system. This can worsen allergy reactions, negatively affect indoor air quality, and contribute to costly hidden structural damage over the years.

How to Properly Seal Ductwork in an Old Home

The 2015 IRC/IECC mandates fully sealed duct systems in new homes, made from energy-efficient materials like mastic, foil tape, and proper insulation. But what if the problem areas are buried deep within the walls or ceilings?

Aerosol sealing technology (AeroSeal) is one way to reach hidden openings inside ductwork. To conduct this method, all vents are blocked except for one access point. The HVAC system is isolated, and a machine is connected to the duct system. It pressurizes the ducts and releases a fine sealant mist that finds and fills small holes that traditional sealing methods cannot access.

This method is effective for addressing small to medium leaks. However, larger holes still need manual sealing with mastic and tape. Technicians carry out a duct leakage test before and after aerosol sealing to assess how much leakage has improved and ensure the treatment was effective.

Common Areas of Duct Leakage

The most frequent area where ducts lose air is at the joints. Ductwork consists of several metal sections pressed together with tight fittings and metal bands, yet these connections are almost never fully airtight.

As your HVAC system operates in varying temperatures across the year, the ducts undergo expansion and contraction. Over time, this movement weakens joint connections, producing gaps and leaks — making duct leakage test essential for both new and older homes in Pitman, NJ.

Many energy auditors look for duct leakage by running their hands along the ducts and using a small tool to measure the width of gaps at the joints. If your duct system wasn’t properly sealed using mastic and approved tape, air leakage is very likely occurring.

What Is an Acceptable Amount of Duct Leakage per Energy Code?

To achieve a passing duct leakage result, your system should measure under 4 CFM per 100 square feet with the air handler installed, or 3 CFM per 100 square feet without the air handler installed. For new construction, you must pass a duct leakage test before the home can be approved for an occupancy certificate.

If your home in Pitman, NJ does not meet duct leakage standards, you are likely overpaying for heating and cooling — and adding unnecessary strain to your HVAC equipment. Meeting the 3–4 CFM requirement is important not only for the inspector, but also for maximizing energy efficiency and comfort in your home.

Your technician will also share expert solutions for tackling leakage problems so you can pass the test, cut down utility expenses, and improve overall comfort and efficiency.

Local Energy Audits — affordable duct leakage test in Pitman, NJ

Local Energy Audits is proud to serve customers across Pitman, NJ and the nearby communities. We specialize in locating and diagnosing duct leakage and energy inefficiencies through blower door and duct leakage tests. Whether your home is newly built or older, we’re here to help.
If you’d like to book a test, call us during business hours or contact us online to request an appointment.

The Duct Leakage Test Steps Explained

A duct leakage test begins by sealing all the ducts and registers with duct mask tape on both the supply and return side.

After the registers are sealed, we fasten the duct tester to the unit or to a main return.

The ducts are then depressurized to 25 Pascals. With the ducts at this pressure, we can use the nanometer to measure the duct leakage.

Schedule Your Duct Leakage Test in Pitman, NJ

Ensure your HVAC system operates efficiently, stays compliant, and performs at peak levels with certified duct leakage test in Pitman, NJ. Whether you’re a homeowner aiming for better comfort or a contractor completing final approval, our certified team ensures fast, accurate, and affordable testing.

We use industry-standard duct blaster equipment and offer on-site guidance to help you pass your test, reduce energy waste, and protect the long-term health of your HVAC system.

Serving homeowners, builders, and contractors across Pitman, NJ with dependable and energy-efficient testing solutions.